IS210BPPCH1 Printed Circuit Board Module GE-IS210BPPCH1
The system receives pitch angle commands from the main controller, collects feedback from the encoder and angle sensor, and outputs PWM drive signals to control the pitch motor, adjusting the turbine blade pitch angle in real time. It captures wind energy when wind speed is normal, and executes feathering protection in strong winds or fault conditions to ensure safe unit shutdown. The board locally performs overcurrent, position error, communication interruption, and limit switch trigger judgments, directly triggering safe feathering without relying on the upper-level controller, possessing independent safety protection capabilities; it supports 10ms/20ms/40ms control frame cycle switching.
Many products are not yet listed. Please contact us for more product information.
If the product model differs from the displayed image, the model number shall prevail. Please contact us for specific product images; we will arrange to take photos in our warehouse for confirmation.
We have 76 shared warehouses worldwide, so it may sometimes take several hours to accurately return the information to you. We apologize for the inconvenience. Of course, we will respond to your inquiries as soon as possible.
Core
Functions
Blade Pitch Closed-Loop Control
Receives pitch angle commands from the main controller, collects feedback from the encoder and angle sensor, and outputs PWM drive signals to control the pitch motor, adjusting the wind turbine blade pitch angle in real time; captures wind energy when the wind speed is normal, and executes feathering protection in high wind/fault conditions to ensure safe shutdown of the unit.
On-site
Signal Acquisition and Processing
Analog Input: 8 AI channels + 1 additional AI channel, acquiring analog quantities such as pitch control unit temperature, voltage, and torque;
Digital Input: 20 DI channels, acquiring signals from limit switches, emergency stop, cabinet door, and motor status switches;
Incremental Encoder Interface: 1 channel, reading the actual blade angle position;

Drive and Relay Outputs
2 PWM power outputs drive the pitch actuator; 2 discrete outputs and 9 relay outputs control contactors, brakes, safety circuits, and fault alarm circuits.
Multi-link Communication and Interaction
Ethernet 10BaseT: Interacts with the Mark VIe master controller via the IONet network;
COM1/COM2, micro 9-pin D-sub, 2 RS-485 ports for docking with pitch drivers, local HMIs, and third-party peripherals;
Local
Fault Monitoring and Protection
The board locally performs overcurrent, position deviation, communication interruption, and limit switch trigger judgments, directly triggering safe feathering without relying on the upper-level controller, possessing independent safety protection capabilities; supports 10ms/20ms/40ms control frame cycle switching.
Working
Principle
Receives target pitch angle commands from the Mark VIe system via IONet Ethernet;
.jpg)
Synchronously acquires encoder angle feedback, various switch signals, and analog sensor signals;
The onboard processor performs closed-loop PID calculations and outputs PWM signals to control the pitch motor;
The relay circuit controls the motor brake and safety chain; in case of limit exceedance, emergency stop, or communication failure, the board directly outputs a feathering command locally to achieve fault protection;
All pitch shaft status and alarms are transmitted back to the Mark VIe main controller for recording and display.
Application
Scenarios
Large onshore/offshore wind turbine generators, Mark VIe platform pitch control system, one board corresponds to one blade pitch shaft control;
Rack-mounted inside the nacelle control cabinet, realizing blade angle adjustment and safe feathering protection;
Common Fault Phenomena and Diagnosis
Blades cannot perform pitch control: PWM output failure, encoder channel failure, abnormal board power supply;
Pitch communication failure reported: IONet network port failure, serial port driver chip failure;
Relay cannot engage/disengage: Onboard relay contacts burned out, safety circuit failure;
.jpg)
Angle drift: AI or encoder input channel failure;
No indicator light upon power-on: Board power conversion circuit failure.
Recommended
related products:
151X1225DF01PC03
151X1225DF01PC03RA
151X1225DE18PC05
MIGIIQI55E00HI00
MIVII1000E00HI00
MVDL1000-47941101
029.381539/00
RS-FSM-1002-001
IS215VPROH1A
IS215VPROH1BE
IS215UCCCS05A
IS215WEPAH2BB
IS215UCCCM04AB
IS215UCCAH3A
IS215WEPAH2BB
IS215WEPAH2BB
More......
PRODUCT TAGS
RELATED PRODUCTS
PLC Dragon Automation
Address: Wanda Plaza, Chengdu, Sichuan Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882