The GE 18L0009WH surge protection capacitor is installed in parallel at the output terminals of motors or generators. Its primary function is to reduce the steepness of the wavefront of transient overvoltages, rather than to directly discharge lightning currents.Grid switching operations, the opening and closing of vacuum circuit breakers, and lightning strikes can generate steep-fronted overvoltages with extremely rapid rise times. Such steep-fronted waves tend to concentrate on the initial turns of the windings, making them highly susceptible to inter-turn insulation breakdown. By leveraging the characteristic that capacitors exhibit low impedance to high-frequency, steep-fronted waves, this device softens the rising edge of the surge voltage, ensures a more uniform distribution of impulse voltage across the windings, and mitigates internal reflected overvoltages. Additionally, it features an integrated discharge resistor that gradually dissipates the charge stored in the capacitor once the surge has passed, preventing any residual voltage from posing a persistent threat to the insulation.

PRODUCT TAGS

  All products listed on this website are specialized items subject to fluctuating market prices.

  Please rely on the quotes provided by our customer service team. As these are new products, the prices displayed may not be final.

  Before placing an order, please confirm the specific model, product details, and pricing with our customer service representatives.


  I. Operating Principle

  In medium-voltage circuits, the opening or closing of vacuum switches—as well as lightning strikes—can generate transient overvoltage waves with extremely steep wavefronts. When these surge waves enter the windings of motors or transformers, the voltage is distributed unevenly. This subjects the turns at the beginning of the windings to intense impulse stress, which can easily lead to the breakdown of inter-turn insulation. The GE 18L0009WH is connected in parallel at the equipment terminals. Leveraging the energy-storage and voltage-buffering characteristics of its internal capacitors, it flattens the steep wavefront of surge voltages, slows the rate of voltage rise, balances the internal voltage distribution within the windings, and reduces the impulse stress on inter-turn insulation. The unit features a built-in discharge resistor that automatically dissipates stored charge once the surge has passed, preventing the accumulation of residual voltage. This device is typically used in conjunction with GE TRANQUELL series surge arresters: the arrester limits the amplitude of overvoltage relative to the ground, while the surge capacitor smooths the wavefront, creating a comprehensive dual-layer insulation protection solution.


  II. Product Advantages

  Proven All-Film Dielectric Design: Utilizing GE’s established all-film, foil-electrode dielectric system, the unit offers low high-frequency loss, high resistance to repeated surge impulses, excellent insulation stability, and minimal capacitance degradation over long-term operation.

  Environmentally Friendly Dielektrol™ Insulating Fluid: The unit uses an eco-friendly, PCB-free impregnating fluid that complies with environmental regulations. It poses a low risk of leakage and is designed to withstand harsh outdoor operating conditions. Hermetically sealed bushing design for flexible installation: The hermetically sealed bushing supports both upright and lateral mounting, accommodating various cabinet configurations and terminal block layouts (note: inverted installation is not supported), ensuring high adaptability.

  Built-in discharge resistor: An integrated discharge circuit is included from the factory, which automatically drains residual charge after power-off. This reduces the risk of electric shock during maintenance and eliminates the need for additional external discharge devices.

  Wide operating range: Suitable for both indoor and outdoor installation. For high-altitude applications, the unit can be derated according to relevant standards, and it is designed to withstand temperature fluctuations typical of industrial environments.

  Standard-compliant and well-integrated: Designed to pair with the GE TRANQUELL series of surge arresters, creating a field-proven surge protection solution for electric motors that aligns with IEEE standards for rotating electrical machinery.


  III. Applicable Industries and Functions

  Power Generation (Thermal, Hydro, and Gas-fired): Protects the stator windings of synchronous generators and synchronous condensers. It guards against surges caused by switching operations and incoming lightning transients, helping to prevent inter-turn short circuits in generators, reduce the risk of unplanned outages, and ensure continuous power supply.

  Oil, Gas, and Petrochemicals: Provides protection for downhole pump units, large medium-voltage drive motors, and compressor motors. In petrochemical facilities—where lightning strikes and frequent switching operations are common—surges can easily damage the insulation of expensive motors. This capacitor helps extend the interval between major motor overhauls and ensures the continuity of industrial processes.

  Mining and Metallurgy: Protects large medium-voltage equipment such as crushers, main ventilation fans, and rolling mill drive motors. Given the high capital cost of such high-power rotating machinery and the significant losses incurred during downtime, this solution suppresses switching overvoltages and slows the aging of winding insulation.

  Rail Transit and Municipal Utilities: Protects large motors in pumping stations and medium-voltage motors used in rail transit infrastructure. It stabilizes motor insulation, reduces electrical faults, and enhances the reliability of power supply for municipal infrastructure. Wind and Photovoltaic Power Plant Substations: Provides winding protection for large medium-voltage asynchronous motors and synchronous condensers, designed to withstand transient surges caused by frequent switching operations in renewable energy power grids.

  Core Value: Protects the inter-turn insulation of rotating electrical machines, reduces insulation breakdown and winding burnout caused by surges, lowers equipment maintenance costs and downtime losses, and enhances the medium-voltage system's resilience against electrical shocks.


  IV. Operating Procedures

  Pre-installation Verification: Verify the model (18L0009WH), rated voltage, and capacitance parameters to ensure the equipment’s rated voltage matches the on-site system. Inspect the housing for deformation, leakage, or damage/cracks on the bushings. Verify the installation altitude; for high-altitude locations, apply the manufacturer’s derating curve.

  Installation and Wiring: Connect the capacitor in parallel as close as possible to the motor/generator output terminals. Keep lead lengths short to minimize lead inductance, which could otherwise diminish the protective effect. Complete grounding in accordance with electrical diagrams and grounding standards. If installing in conjunction with a surge arrester, strictly follow the specified protection layout. The unit should preferably be installed upright or on its side; upside-down installation is prohibited.

  Pre-energization Testing: While the system is de-energized, use an appropriate high-voltage insulation tester to measure insulation resistance and capacitance. Compare these values against the nameplate specifications to ensure there are no anomalies. Check all terminals to ensure they are securely fastened, with no loose or poor connections.

  Commissioning: Ensure all personnel have cleared the high-voltage area before energizing the system. Record the initial operating parameters upon startup. During normal operation, the unit functions passively to absorb surges and requires no active adjustment.

  Shutdown and Maintenance: After the system is de-energized, wait for the internal discharge resistors to fully dissipate the stored charge. Subsequently, use a dedicated grounding rod to short-circuit and further discharge the unit. Only after confirming that no residual voltage remains should you touch the terminals. V. Precautions

  High-Voltage Safety First: This product is a 13.8 kV medium-voltage device. All installation, testing, and maintenance tasks must be performed by certified high-voltage electricians. Strict adherence to safety protocols—including power disconnection, voltage verification, grounding, and the "lockout/tagout" procedure—is mandatory. Note that capacitors may retain a high-voltage charge even after power is disconnected; they must be fully discharged.

  Installation Constraints: The unit may only be installed in an upright or lateral position; inverted installation is strictly prohibited. The installation site must be well-ventilated and kept away from heat sources, corrosive gases, and areas prone to dust accumulation.

  System Integration: Using this device alone offers limited protection. It is recommended to pair it with a GE TRANQUELL surge arrester to provide comprehensive protection against both voltage amplitude and wavefront surges. Do not alter the length or cross-sectional area of the leads.

  Environment and Service Life: Avoid prolonged exposure to immersion or highly corrosive environments. Conduct regular inspections, focusing on the housing for oil leaks, the bushings for surface tracking (creepage), and the terminals for overheating. If any leakage, bulging, or insulation breakdown occurs, the unit must be taken out of service immediately and replaced.

  Model Information: The GE 18L0009WH is a discontinued spare part. Before procurement and replacement, verify the existing protection scheme to ensure all parameters match; failure to do so may result in the loss of protection.

  Prohibited Modifications: Do not disassemble the housing or replace the insulating medium. Do not operate the device above its rated voltage for extended periods, as overvoltage accelerates the degradation of the insulating medium, potentially leading to insulation breakdown or oil leakage.


Recommended products:
151X1207CK02SA12
IS200EBKPG1C
IS200JPDCG1A-CB
IS200JPDFG1A
IS200JPDFG1A-ED
IS200JPDBG1A-BB
IS200WROBH1A
IS200WROBH1ABA
IS200JPDHG1AAA
IS420YAICS1B
IS200TRTDH1C
GF868-1-11-10114
MVR1600-4601
MVR1600-4601-A
More......

PRODUCT TAGS

RELATED PRODUCTS

PLC Dragon Automation

Address: Wanda Plaza, Chengdu, Sichuan Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882

Copyright © 2023~2024 PLC Dragon Automation